1. INSTALLATION
a. Choice of location
Avoid exposure to high variations in temperature and direct sunlight. Never install close
to a water supply or sink! Do not install the detector close to air conditioning or heating
systems. Choose your location carefully so that nothing can hinder detection and so that
the infrared sensor works properly. Avoid obstacles – the detection field must be free.
b. Connecting
For ceiling installation, the detector is connected between the original light switch and
the light. It is powered by 4 wires – be sure to respect the colours :
230V = L : phase - brown - N : neutral - blue.
device to connect = L' : phase - brown - N : neutral - blue.
Connect the lamp to a Class II light fixture (not to be connected to earth).
• Shut off the power at your electrical board,
• remove your existing light fixture if necessary.
1
2
Cable
Sorties
output
de câbles
9