Use the
buttons to select the period and then press OK to confirm and save
the setting. Then press MENU once or more to return to the Production Screen.
You can also exit without saving the setting by pressing MENU.
When a polarity change is taking place the unit will
Chang. polarity
enter in pause mode during 10 minutes. This will be
remaining: 8 min
indicated by the screen on the left showing the
remaining pause time.
3. T V I readings
MAIN MENU
4 T V I readings
This menu allows you to read the temperature
inside the control unit, the voltage applied to the
cell and the current passing through it. These
parameters can be very useful when servicing or
T=
29.8ºC
diagnosing.
V= 23.40V I=3.4A
4. LCD contrast
Go to the MENU 6 LCD contrast and press OK
MAIN MENU
6 LCD contrast
Adjust the LCD contrast using the Λ V keys.
LCD contrast
Press OK to save and exit.
- ■ ■ ■ ■ ■ ■ +
5. Fault messages
LOW WATER
LEVEL IN CELL
This screen is displayed when the probe detects no water and the control system
stops the production. Verify that there is water in the cell and that its level reaches
the top where the probe is located. A low water level can result from operating the
chlorinator with the pump not working. In this case switch off the chlorinator
immediately.
THE CHLORINATOR SHOULD NEVER BE POWERED IF THE PUMP IS NOT
WORKING OR IF THE WATER IS NOT FLOWING SUFFICIENTLY. THE
CHLORINATOR POWER SUPPLY SHOULD DEPEND ON THE PUMP POWER
SUPPLY.
A low water level in the cell may also be due to a dirty filter, an obstructed circuit
or to a pump not powerful enough. As soon as the water level is restored the fault
disappears.
26
Célula
Introduzca la célula en el vaso. LA ABERTURA LATERAL DEBE COINCIDIR CON
LA ENTRADA DE AGUA DEL VASO. Asegúrese de que la junta se encuentra en su
lugar y coloque la rosca. A continuación, conecte el cable de la célula en los bornes
de la célula. .
NOTA: Los bornes de la célula deben ser apretados moderadamente y siempre a
mano. No utilice nunca una herramienta porque podría dañar la célula. La
estanqueidad de la célula está asegurada por el sellado interior.
Una buena filtración es fundamental para la cloración salina.
Verifique que el filtro y sus elementos filtrantes están en óptimas
condiciones de trabajo.