Descargar Imprimir esta página

Daikin Altherma FWXV10ABTV3 Manual De Instalación página 7

Convector para bomba de calor

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
U
I
S
2.1
Positioning the unit
Avoid installing the unit:
-
in positions subject to exposure to direct sunlight;
-
in proximity to sources of heat;
-
in damp areas or places with probable contact with
water;
-
in places with oil fumes
-
in places subject to high frequency radio waves.
Make sure that:
-
the wall on which the unit is to be installed is strong
enough to support the weight;
2.2
Installation modes
The following descriptions of the various mounting phases
and the relative designs refer to a version of the machine
with fixtures on the left.
The operations for the mounting of machines with fixtures
on the right (R) are exactly the same.
Only the images are to be considered as a mirror image.
To ensure that the installation is performed correctly and
2.3
Minimum installation space
Figure
indicates
the
minimum
between the wall-mounted cooler-convector and furniture
present in the room.
20 mm
INSTALLATION
mounting
distances
20 mm
-
the part of the wall interested does not have pipes or
electric wires passing through;
-
the interested wall is perfectly flat;
-
there is an area free of obstacles which could interfere
with the inlet and outlet air flow;
-
the installation wall is preferably an outside perimeter
wall to allow the discharge of the condensation outside;
-
in case of ceiling installation (FWXM-series) the airflow is
not directed towards persons.
that the appliance will perform perfectly carefully follow the
instructions indicated in this manual. Failure to respect the
rules indicated not only can cause malfunctions of the
appliance but will also invalidate the warranty and hence
DAIKIN EUROPE N.V. shall not respond for any damage to
persons, animals or property.
400 mm
INSTALLATION
EN
7

Publicidad

loading