For example: the shutter maximal weight is 850kg and the door width is 11m, what size of
diameter and what kind of model shall we choose?
a) From Y- coordinate select 850kg as line 1. Then from X- coordinate select 11m as line 2 to reach
the across of point A, along right direction to the next point B. The pipe diameter and thickness Ф
273× 7 in pipe diameter line of point B, that is what we want.
b). From point B up to the closest model line at point C, the position of model 1401N. m is what we
want.
The deflection should be controlled less than 1/ 400, or when the door is more than 5m in width,
with more than 3 mm thickness and self- weight is above 350kg, 5 seamless pipe with more than
3mm thickness and zinc plated must be used to prevent pipe axle from bending which would lead
to overload and a short life of motor, and even directly damage teeth of motor's gear.
NOTe:
1. After completing the installation, insert the fuse into the controller and then plug
it in.
2. The controller cannot work if there is no power and the battery is damaged. If
power is supplied, the controller can open and close the roller door.
3. If the controller is in stanby mode for two days or more, or if it is used continuously
in the absence of electricity and the low voltage warning appears or turns o
automatically, use it after fully charging.
4. If you do not intend to use the controller for a long time, unplug the power supply
and remove the fuse from the battery. (You must charge the battery for at least 20
hours every 80 days. Install the fuse before charging the battery)
5. The battery of this controller is a 12V / 4.5 Ah rechargeable lead acid battery, you
can buy a similar rechargeable lead acid battery and replace it. Do not use a
non-rechargeable battery or a di erent battery, as it may explode or cause a re.
ANUNCIO
1. Por favor instale el fusible de 15A antes de usar.
2. Esta caja de control puede ser usada normalmente. si la batería está dañada use únicamente la alimentación de la red.
3. Cuando la caja de control ha estado en servicio continuo o en un tiempo de espera demasiado largo y la caja muestra alarma de bajo voltaje,
auto apagado, por favor recargue antes de usar nuevamente.
4. Si va a estar sin uso durante un largo tiempo, por favor retire el conector y el fusible de 15A. Pero asegúrese de cambiarlo en un tiempo no
menor a 20 horas cada 80 días.
5. Dentro de esta caja de control hay una batería de 12V/a.5Ah, El cliente puede comprarla y reemplazarla.
Opening your life
Opening your life
6
Opening your life
ON
LOW VOLTAGE
CHARGE
5
HULK550DC
Code:
UP
STOP
DOWN
www.accessmatic.com