8.4.
Replacing/installing the suction filter.
This operation must be performed with the machine off and ignition key removed
Every 50 working hours or as necessary, check the suction filter as follows:
Lift the back guard (suction fan housing) (fig. I). Make sure it is blocked in the open
position by the safety device (fig. V).
Unscrew the four screws (fig. L).
Disconnect the connector on the filter shaker (fig. L).
Remove the filter from its housing (fig. L).
Thoroughly clean the filter with a vacuum cleaner or replace it (fig. M).
To mount the filter, follow the same procedure in reverse.
Close the back guard by releasing the safety device (fig. V).
8.5.
Fuses: replacing
This operation must be performed with the machine off and ignition key removed
turn the ignition key (fig. C, ref. 1) to the "0" position.
lift the fuse compartment cover (fig. C ref. 18 - fig. N).
check the fuses (fig. N).
replace with a new fuse.
close the cover.
Fuse table: For the complete fuse table, see the spare parts catalogue.
Never use a fuse with a higher amperage than specified.
If a fuse continues to blow, the fault in the wiring, boards (if present) or motors
must be identified and repaired. Have the machine checked by qualified personnel.
8.6.
Replacing/installing flaps
This operation must be performed with the machine off and ignition key removed
Every 50 working hours or as necessary, check the flaps and if worn, proceed as follows:
8.6.1. Side flaps
• Open the side guards (fig. O - fig. P).
• Using a screwdriver, unscrew the flap fixing screws (fig. O - fig. P).
• Replace the worn flaps (fig. O - fig. P).
To mount, follow the same procedure in reverse.
8.6.2. Rear flap
• Remove the left side guard (fig. E).
• Remove the brush compartment cover (fig. F).
• Remove the rear flap (fig. Q, ref. 1).
• Replace the worn rear flap (fig. Q, ref. 1).
To mount, follow the same procedure in reverse.
8.6.3. Front flap
• Remove the two side brushes (fig. H).
• Using a screwdriver, unscrew the worn front flap fixing screws (fig. Q - ref. 2).
• Release the flap from the pronged clip.
! DANGER
IMPORTANT
IMPORTANT
! DANGER