6. Specification
Function
Range & Resolution
50.00 ADC
DC Current
1000.0ADC
50.00 AAC
AC Current
True RMS
1000.0AAC
(50 to 60Hz)
All AC Current ranges are specified from 5% of range to 100% of range
500.00uA
uA Current
5000.0uA
500.00 mVDC
5.0000VDC
DC Voltage
50.000 VDC
500. 00 VDC
600.0 VDC
500.00 mVAC
5.0000 VAC
AC Voltage True
50.000 VAC
RMS
500. 00 VAC
(50 Hz to 1000 Hz)
0600.0 VAC
All AC voltage ranges are specified from 5% of range to 100% of range
500.00Ω
5.0000KΩ
50.000KΩ
Resistance
500.00KΩ
5.0000MΩ
50.000MΩ
500.00nF
5000.0nF
Capacitance
50.00.μF
500.0.μF
5.000mF
50Hz
500Hz
5kHz
Frequency
50kHz
500kHz
5MHz
10MHz
12
Accuracy (% of reading)
±(2.5%+5digits)
±(2.5%+5digits)
DC: ±(1.0% + 6 digits)
AC: ±(1.5% + 30 digits)
DC: ±(1.0% + 6 digits)
AC: ±(1.5% + 30 digits)
± (1.0% + 8 digits)
± (0.1% + 4 digits)
±(1.0% + 30 digits)
± (1.0% + 9 digits)
± (1.0% + 5 digits)
± (2.0% + 10digits)
± (3.0% + 10 digits)
±(3.5% reading + 40digits)
±(3.5% reading + 10digits)
±(5% reading + 10 digits)
± (0.3% reading + 2 digits)
rspro.com
50000 count TRMS heavy Duty AC/DC clamp meter with
Function
Range & Resolution
5.0 to 95.0%
Duty Cycle
Pulse width: 100μs - 100ms, Frequency: 10Hz to 10kHz
-100.0 to 1000.0°C
Temp(type-K)
(probe accuracy
-148.0 to 1832.0°F
not included)
(probe accuracy not included)
7. General Specifications
Clamp jaw opening
1.9" (48mm) approx.
Display
Dual 50,000/50,000 count backlit LCD
Continuity check
Threshold 50Ω; Test current < 0.5mA
Diode test
Test current of 0.3mA typical; Open circuit voltage 2.8VDC typical
Low Battery indication
Battery symbol is displayed
Over-range indication
'OL' display
Measurement rate
2 readings per second, nominal
Peak detector
>1ms
Thermocouple sensor
Type K thermocouple required
Fuse
500mA, ceramic fast blow
Input Impedance
10MΩ (VDC and VAC)
AC bandwidth
50 to 400Hz (AAC and VAC)
AC response
True rms (AAC and VAC)
3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60Hz and 5% to 100%
Crest Factor
of range)
Operating Temperature
5°C to 40°C (41°F to 104°F)
Storage Temperature
-20°C to 60°C (-4°F to 140°F)
Operating Humidity
Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity
<80%
Operating Altitude
7000ft. (2000meters) maximum.
Battery
One (1) 9V Battery (NEDA 1604)
Auto power OFF
After approx. 30 minutes, with disable
Dimensions & Weight
9.1x3.0x1.6" (230x76x40mm); 11.1 oz. (315g)
For indoor use and in accordance with the requirements for double insulation
Safety
to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and
Category II 1000V, Pollution Degree 2.
Approvals
CE
rspro.com
dual Type K inputs / English
Accuracy (% of reading)
± (1.0% reading + 2 digits)
±(1.0% reading + 2.5 °C)
±(1.0% reading + 4.5°F)