source.
20. Do not operate or disassemble charger if it has received a sharp blow, been dropped, or otherwise
damaged in any way; take it to a qualified serviceman. Incorrect use or reassembly may result in a risk
of electric shock or fire.
21. All maintenance work must be conducted by qualified electricians.
22. Never disassemble the device, incorrect assembly may cause electric shock or fire.
23. For the protection class is IP20. The product shall not be used outside the room, where it is the rainy
and snowy.
24. As the casing can generate heat during charging. it is prohibited to cover the vent of casing.
Product View:
C
D
E
F
G H
B
1. Positive( + ) and negative( - ) polarity clamps
2. LCD display, which displays the battery voltage or percentage of the charging battery. You can select
the displayed values by press the "Display" button
3. LED light to display which value is selected.
4. LED light to indicate charging process, if the light flicks, it means that the charger is running at
reconditioning mode. It lights up permanent during charging.
5. Red LED light up?means the output clamps is wrong connected. You should connect red clamp to the
positive terminal of the battery and black one to the negative.
6. Charging battery select button, according to the battery you connect, you can push the "Battery"
button to choose different battery types and charging voltage 6V or 12V. If wrong charging voltage is
selected, the LCD display will display"FUL" and there will have no output current
7. LED Display and Engine Start function select button, according to your requirement, you can choose
9