• Humidity Set Control Pads: The humidity level can be set within a range of 35% RH (Relative
Humidity) to 85% RH in 5% increments. For drier air, press the (<) pad and set to a lower percent
value (%). For damper air, press the (>) pad and set a higher percent value.
• TIMER Set Control Pads: Use the Up/Down pads to set the Auto start and Auto stop time from
0.0 to 24.
6. POWER Pad: Press to turn the dehumidifier on and off.
7. DISPLAY: Shows the set % humidity level from 35% to 85% or Auto start/stop time (0‒24) while
setting, then shows the actual room humidity level percentage (within 5% accuracy) in a range of
30% to 90% RH.
Error Codes and Protection Code:
AS - Humidity sensor error. Unplug the unit and plug it back in. If error repeats, call for service.
ES - Temperature sensor error. Unplug the unit and plug it back in. If error repeats, call for service.
P2 - Bucket is full. Bucket is full or bucket is not in right position. Empty the bucket and replace it in
the right position.
EC - Refrigerant leakage detection.
E3 - Unit malfunction. Unplug the unit and plug it back in. If error repeats, call for service.
OTHER FEATURES
Bucket Full Light
Glows when the bucket is ready to be emptied.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced in
the proper position. When the setting humidity is reached, the unit will be shut off automatically. For
some models, the fan motor will continue operating.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to
run until the frost disappears.
3 Minute Pause
After the unit has stopped, it can not be restarted until 3 minutes have elapsed. This is to protect the
unit. Operation will automatically resume after 3 minutes.
Check Filter Feature
The system starts to count the hours of operation once the fan motor is used the first time. The check
filter feature is activated when the accumulated operation time reaches 250 hours or more. At that
point, the Reset light (Clean filter indicator light) will flash at one time per second to alert the user that
the filter needs cleaning. After cleaning the air filter, press the Filter pad and the Reset light (Clean
filter indicator light) will turn off.
Auto-Restart
If the unit is turned off unexpectedly due to a power cut, it will restart with the previous function
settings automatically retained when the power resumes.
Setting the Timer
• When the unit is on, press the TIMER pad and the TIMER Off indicator light illuminates. It