Descargar Imprimir esta página

Glacier bay IRENA HD873X-8E01 Guía De Uso Y Mantenimiento página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation (continued)
4
Back to back installation
NOTE: If you are not making a reverse or back to back
installation, skip this step and continue with the step 5.
If the hot and cold inlets are reversed (hot on
right and cold on left), remove bonnet nut (1)
from the valve body (D) with reversed supply
connections. Rotate the cartridge (2) 180°,
so H appears on the right. Install the cartridge,
making sure that the key is fully engaged with
the slot in the valve body (D). Slide the bonnet (1)
over the cartridge (2) and thread them onto the
valve body (D). Tighten bonnet (1) securely with
adjustable wrench until the o-ring on the valve
body (D) is covered completely.
NOTE: Never install the valve body (D) upside down!
The appropriate locking torque of the bonnet (1) is
10~12 N·M. Do not overtighten.
3
2
1
Reverse
installation
Hot
Cold
Reverse installation
Normal
installation
(changes
not required)
Cold
D
Hot
H
Normal installation
Hot
H
5
Installing the shower arm
Insert the long end of the shower arm (B) through
the shower ange (A), and wrap thread sealant
tape (not included) around the long end of the
shower arm (B) in a clockwise direction, as shown.
Install the long end of the shower arm (B)
into the pipe elbow inside the wall. Carefully
tighten the shower arm (B) with a clean strap
wrench. Do not overtighten.
Wrap thread sealant tape around the pipe
threads of the tub spout outlet (1, not included)
in a clockwise direction, as shown.
Connect the tub spout outlet pipe to the lower
pipe elbow (2, not included). Tighten the elbow
and tub spout outlet pipe connections with a
strap wrench.
NOTE: Do not cut the outlet pipe (1, not included) before
the pressure test procedure.
Cold
9
Please contact 1-855-HD-GLACIER for further assistance.