Trouble Shooting:
1.
Blower does not reach operating speed when starting:
1.1 Check that the incoming voltage and frequency corresponds with the motor data plate.
1.2 Check the connections on the motor terminal block.
2.
Motor starter cuts out blower:
2.1 Problem as per 1.1 and 1.2.
2.2 Incorrect setting on the motor starter.
2.3 Motor starter trips too fast.
Solution: Use a motor starter with a time delay trip (version as per IEC 947-4).
2.4 Blower is overloaded, i.e. pressure difference is too high.
Solution: Increase the inlet or outlet diameter of the application, on pipework increase the diameter of the pipework, avoid restrictions in the
line. Limit the pressure difference by limitation valves (optional extra).
2.5 Motor rating selected was too small.
Solution: If available use a blower with the next motor size (exchange of the motor only is not possible).
3.
Required pressure difference cannot be achieved:
3.1 Blower or motor rating selected, was too small.
3.2 Filters are contaminated.
3.3 Pressure loss into pipework too high.
Solution: Use bigger pipe diameter, avoid restrictions.
3.4 Leaks on the system.
4.
Blower operates at an abnormally high temperature:
4.1 Ambient or suction temperature is too hot.
4.2 Pressure difference is higher than permitted.
4.3 Cooling air flow is restricted.
5.
Exhaust noise (vacuum pump) or suction noise (compressor) are unacceptable:
Solution: Use an additional silencer ZGD (optional extra).
6.
Change solenoid valve or change over valve ZWS (accessory) does not work:
6.1 Check that the incoming voltage and frequency correspond with the information on the solenoid.
6.2 Change over valve is contaminated.
Solution: Dismantle and clean.
Appendix:
Repair on Site: For all repairs on site an electrician must disconnect the motor so that an accidental start of the unit cannot happen.
All engineers are recommended to consult the original manufacturer or one of the subsidiaries, agents or service agents. The address of the nearest
repair workshop can be obtained from the manufacturer on application.
After a repair or before re-installation follow the instructions as shown under the headings "Installation and Initial Operation".
Lifting and Transport: To lift and transport units SAP 180 to SAP 1500 the eye bolt on the pump must be used.
The weight of the blowers are shown in the accompanying table.
Storage: SAP units must be stored in dry ambient conditions with normal humidity. We recommend for a relative humidity of over 80% that the pump
units should be stored in a closed container with the appropriate drying agents.
Disposal: The wearing parts (as listed in the spare parts lists) should be disposed of with due regard to health and safety regulations.
Spare parts lists:
E 545/ 1 • SAP 50 —> SAP 300; SAP 380, 450, 530 (4 kW + 4,8 kW)
E 545/ 2 • SAP 380, 450, 530 (5,5 kW –> 9 kW); SAP 710; SAP 1060; SAP 1500
SAP
Noise level (max.)
Sound power
Weight (max.)
Length (max.)
Width
Height
50
90
50 Hz
75
81
dB(A)
60 Hz
77
81
50 Hz
-
-
dB(A)
60 Hz
-
-
kg
16
17
mm
328
340
mm
234
251
mm
267
297
110
150
180
220
300
81
87
86
88
82
87
87
89,5
-
91
94
98
-
92
94
99
100
24,5
24,5
34
42
362
369
411
429
464
282
282
332
370
386
322
322
381
414
443
380
450
530
710
87
86
90
93,5
92,5
91
86
90
92
94
95
92
99
100
99
92
99
100
101
53
58
95
88
125
490
608
634
664
432
450
471
534
486
525
561
617
1060
1500
99
99
99
100
108
108
108
108
200
201
764
790
534
534
639
606
8.08
/ PM7