Fault
The cleaning performance of
the
DuoClean worsens.
Streaks are forming.
Possible cause and solutions
– Check whether the sealing lip frames are able to move.
The cleaning cloth may be attached to the cloth holder frame at an
angle and be obstructing the sealing lip frames.
– Check whether the cleaning cloth is evenly fixed on the cloth
holder frame.
It is possible that the suction channel is blocked.
3
– Open the inspection flap on the left hand side of the DuoClean
to clear any blockages. This can be done by inserting a coin into
the groove (1).
The magnetic latch on the inspection flap comes open (2). You
can now clearly see inside the suction channel.
– Remove any objects that are blocking the suction channel (3).
To do this, use an appropriate blunt object (e.g. screwdriver,
crochet hook).
– Press the inspection flap down to close it again.
The magnetic latch on the inspection flap will click into place
and it is now firmly closed.
It is possible that the cleaning cloth is soiled excessively.
– Change the cleaning cloth, see
[} 58].
It is possible that the cleaning cloth is too dry.
– Check the LED wave symbol on the DuoClean. If it is lit up
yellow, you need to fill the tank, see
inserting the tank
– Moisten the cleaning cloth by pressing the function key, see
Single application of moisture to a dry cloth
– Also increase the moisture setting if necessary using the
function key, see
mode [} 53]
It is possible that the cleaning cloth was not washed prior to first
use.
– Wash the cleaning cloth prior to first use, see
It is possible that too much cleaning agent was used.
– Repeat the cleaning process with a new cleaning cloth and
clean water.
There may be residual quantities of old care products and cleaning
agents on the floor.
– Repeat the cleaning process until it improves; a thorough clean
might be required.
It is possible that the cleaning cloth is soiled excessively.
Replacing the cleaning cloth
Removing, filling and
[} 52].
Automatic application of moisture and dry
[} 54].
After use
[} 59].
63