Descargar Imprimir esta página

CORBERO ZEN-4GS BUT Manual De Instrucciones página 61

Publicidad

Idiomas disponibles

Idiomas disponibles

3. INSTALLATION AND PREPARATIONS FOR USE
always use the seals provided in the gas conversion kit. The seals used during connection should also
be approved to be used in gas connections. Do not use plumbing seals for gas connections.
Remember that this appliance is ready to be connected to gas supply in the country for which it has
been produced. The main country of destination is marked on the rear cover of the appliance. If you
need to use it in another country, any of the connections in the figure below can be required. In
such a case, learn the appropriate connection parts and obtain those parts to perform a safe
connection.
It is required to call the authorized service to be able to make the gas connections appropriately
and in compliance with safety standards.
!
ATTENTION!
Surely do not use any match or lighter for control of gas leakage
3.5 Gas conversion
Caution : The following procedures must be undertaken by authorized service people.
Your appliance is adjusted to be operated with LPG/NG gas. The gas burners can be adapted to
different types of gas, by replacing the corresponding injectors and adjusting minimum flame length
suitable to the gas in use. For this purpose, following steps should be performed
Changing injectors:
Hob Burners
:
Cut off the main gas supply and unplug from the electric mains
Remove the burner cap and the adapter(Figure 9).
Unscrew the injectors. For this, use a 7mm spanner(Figure 10).
Replace the injector with the ones from the gas conversion kit, with corresponding diameters
suitable to the type of gas that is going to be used, according to the information chart (which is
also supplied in the gas conversion kit).
Figure 7
.
10
.
:

Publicidad

loading

Este manual también es adecuado para:

Zen-4gs nat