OPERATION
SHORT-TERM SETTING OF A REMOTE CONTROL
This function makes it possible to store a remote control temporarily, for example, with
the purpose of setting the limit switches during assembly in the factory. A later final
saving of the remote control will be possible using the appropriate command sequence
(see: "SETTING THE FIRST REMOTE CONTROL"). The operations described below can be
carried out only when the control unit has just come out of the factory or after a full
memory clearing (see: "FULL MEMORY CLEARING"). The control unit makes the following
operations possible only within the time limits described in order to make sure that the
short-term setting is used only in the installation or factory setting phase and not during
daily use. Power up the control unit, make sure that no other control units having an
empty memory are powered up in the same operating range.
Within 30 seconds after start, press the B and C buttons simultaneously until the motor
gives a confirmation signal.
The remote control will remain stored for 5 minutes, while the control unit is
powered up. After 5 minutes or when the control unit has its power cut off, the remote
control will be cancelled.
T1: First remote control to be stored
Pressing one of the two buttons and releasing,
the motor drives to the desired direction until it reaches
the limits.
SPECIAL FUNCTIONS
B
+
+
C
B
C
T1
STOP
38
To stop the motor
before reaching the
limits press again the
same button.
If during the movement
the other button is
pressed
the
motor
changes the direction.