12. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
When working with spray attachments and during
temporary use outdoors, the device must be
connected to a residual current circuit breaker with a
trigger current of 30 mA or less.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been
improperly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are
disconnected from electrical power when checking for
damage.
Electrical connection cables must comply with
the applicable VDE and DIN provisions. Only use
connection cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
Three-phase motor 400 V~ / 50 Hz
28 | GB
Mains voltage 400 V~ / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE). Extension cables must have a
minimum cross-section of 1.5 mm². Mains fuse protec-
tion is 16 A maximum.
When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary). Turn pole inverter in the
machine socket.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
13. Cleaning
m Attention!
Pull out the mains plug before carrying out any
cleaning and maintenance work! Risk of injury from
electric shock!
m Attention!
Wait until the equipment has cooled down completely!
Danger of burning!
m Attention!
Always depressurise the equipment before carrying
out any cleaning and maintenance work! Risk of injury!
We recommend that you clean the device directly after
every use.
• Keep the device as free of dust and dirt as possible.
Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap.
Do not use any cleaning products or solvents; they
could attack the plastic parts of the device. Make
sure that no water can penetrate the device interior.
• The hose and injection tools must be disconnected
from
compressor must not be cleaned with water,
solvents or similar.
www.scheppach.com
the
compressor
before
cleaning.
The