Descargar Imprimir esta página

Pfannenberg PTF Serie Instrucciones De Servicio página 69

Ventiladores con filtro superiores / filtros de escape superior 230 / 115 v

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 162
ENG
4.6.2.2
Mains connection PTF 1200
Fig. 11: Mains plug PTF1200
1
Mains plug
2
Mating plug
NOTE
Protective conductors in the mains connection cable are not regarded as potential equalization conductors.
Prerequisite
DANGER – Danger to life due to electric shock. Make sure that the unit is voltage-free.
All general requirements for safe and reliable operation are fulfilled.
Procedure
1.
Connect to mains as shown in the circuit diagram (terminal designation).
2.
Open the cage clamp terminal of the mating plug with the flat screwdriver and connect the cables on the mating plug.
ATTENTION – Damage to the cage clamp terminal.
Firmly insert the screwdriver into the cage clamp terminal. Never turn it, otherwise the cage clamp terminal will be
damaged.
3.
Plug the mating plug into the mains plug.
4.
Before switching on, make sure that the mains voltage matches the data on the type plate.
Electrical connection of the top filterfan is completed.
Operating Manual | Top Filterfans / Top Exhaust Filter | – 230 / 115 V | 086150000
3
Cable 1.5 to 4 mm², stripping length 8 to 9 mm
4
Screwdriver (flat, max. 3.5 mm)
29/40

Publicidad

loading