Installation and connection
B, C, D
Set-up the unit
• Install the unit flood protected in a horizontal position.
Ensure that the unit is installed with a safety distance of at least 2 m from the water.
• Install the unit above the level of the water, otherwise it will be damaged by water flowing back.
Damage resulting from incorrect installation is not basis for a claim within the framework of the guarantee or warranty.
Connect the unit
• Keep the air hose as short as possible and lay it well protected.
• Connect the aeration stone to the air hose and position the aeration stone in the pond.
• Attach the free end of the air hose to the air outlet on the unit.
Start-up
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Remedy of faults
Malfunction
The unit is not operating
The unit does not deliver any air or the amount
delivered is insufficient
The unit is unusually loud
Wear parts
Aerator stones, air filter and membranes are wear parts and are not covered by our warranty.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Cleaning the air filter
How to proceed:
3.
0.
E
1. Remove the filter holder from the top section of the housing with the aid of a screwdriver.
2. Remove and shake out the filter fleece or replace if necessary.
3. Push the filter fleece into the filter holder.
− Pay attention to the O ring as it holds the filter holder in the housing.
4. Reassemble the unit in the reverse order.
Replace membranes
An aerator motor is located under the aerator housing. If the delivery rate of the aerator pump decreases, it is necessa-
ry to replace the two membranes. To do this it is necessary to open the housing and remove the aerator motor.
Note!
• Never operate the unit with defective membranes.
• Always replace both membranes even when only one membrane is defective. The procedure is identical for
both membranes.
• Please contact your specialist dealer if you do not wish to undertake the replacement yourself.
23589-02-14_GA_PondoAir Set 200-11 11
Cause
No mains voltage
The aeration stones are soiled
The air filter is soiled
Air hose kinked or porous
Membrane is defective
Membrane is defective
- GB -
Remedy
Check mains voltage
Clean or replace the aeration stones
Clean or replace the air filter
Lay the air hose without kinks or replace
Replace both membranes
Replace both membranes