Channel
Function
Control
15
(5 second activation
delay)
13
QUICK REFERENCE GUIDE
Value
Percent/Setting
000  009 No function
010  014 Blackout during pan/tilt
015  049 No function
050  054 Pan reset
055  059 Tilt reset
060  064 Zoom reset
065  069 No function
070  074 Reset all
075  079 No function
080  084 Reverse pan and tilt movement
085  089 Reverse pan movement
090  094 Reverse tilt movement
095  099 Normal pan movement
100  104 Normal tilt movement
105  109 Normal pan and tilt movement
110  119 No function
120  124 Fan ECO mode
125  129 Fan full speed
130  134 Fan auto mode
135  139 Fast dimmer curve
140  144 Smooth dimmer curve
145  149 Linear curve
150  154 Square curve
155  159 I Square curve
160  164 SCurve
165  169 White mode on
170  174 White mode off (full mode)
175  179 Color calibration off (single color)
180  184 Color calibration on (single color)
185  239 No function
240  247 Color calibration on
248  255 Color calibration off