Description
3.1 Construction
The inverter consists of the following components:
1 Rotary switch for switching on/off and setting the switch-on threshold (see
chapter 5.2).
2 LED for indicating the operating modes
3 Battery cable: red = +, approx. 1.5 m long
4 Battery cable: black = –, approx. 1.5 m long
5 Power cable, 2-core, approx. 1.5 m long
6 RJ45 connection, only for communication with PA Link1, see the PA Link1
operating instructions
3.2 LED statuses
LED col-
our
–
Green
Red
Red-
green
Explanation:
Blinking slowly (1 second):
Blinking quickly (0.1 second):
3.3 Rotary switch settings
Setting
Off
Standby
left
Standby
centre
Standby
right
On
All On
754.923 | Z02 | 15.51
Status
Meaning
Dark
Power supply switched off
Permanently illuminated Consumer device switched on
Blinking slowly
Standby operation, no consumer device
was recognized
Blinking slowly
System error. Inform your installation com-
pany and have them check the system
Blinking quickly
Overcurrent
Permanently illuminated Overheating
Blinking slowly
Battery undervoltage or low charge state
Blinking quickly
Battery overvoltage
Sensitivity
Load detection
–
Power supply switched off
Low sensitivity
Power supply only starts reacting at heavy loads
Medium sensitivity Power supply starts reacting at medium loads
High sensitivity
Power supply starts reacting at small loads
–
Power supply always switched on
–
Setting for parallel operation, see the separate
PA Link1 operating instructions, in individual
operation the same as setting "On"
19