Observations
The motorised product
stops too soon.
Setting is not allowed. The
drive moves briefly 3 times
in one direction and 3 times
in the other direction. Red
LED blinks 3 times and 3
times intermittently.
12
Possible causes
Drive position is out of the
end limits. Red LED blinks 2
times intermittently and
continually.
The drive is neither set nor
paired. Orange LED lights
fixed on.
The thermal protection has
activated. LED blinks red
continuously.
The end limits are
incorrectly set.
The motorised product has
exceeded recommended
weight limit.
The drive battery is low.
Red LED blinks 5 times
when any button of a
paired control point is
pressed.
Maximum number of
control points reached.
Maximum/minimum value
of the setting is reached.
End limits are too close
©
Copyright
2021 SOMFY ACTIVITES SA. All rights reserved.
Roll Up Basic 28 WF RTS Li-ion
Solutions
Proceed to Readjusting
the end limits [} 13].
Proceed to
Commissioning [} 8].
Wait for the drive to cool
down (LED will switch off)
Reset the end limits
referring to Readjusting
the end limits [} 13].
Replace the motorised
product.
Charge the battery.
Erase control points from
memory to add a new
control point referring to
Erasing control points
from memory [} 15].
Perform correct setting.
Readjust the end limits
referring to Readjusting
the end limits [} 13].