Descargar Imprimir esta página

Emos P56500 Manual Del Usuario página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 99
GB | Smoke Detector
This manual contains important safety information regarding the installation and operation of the
detector. Carefully read this manual and store it safely for future use. Familiarise other residents of
the building with the operation of the detector.
Create an evacuation plan in case of fire and perform a drill every month. All residents of the building
should be familiar with the detector signals in order to be able to immediately react to them.
The detector allows the detection of a slow burning flames accompanied by thick black smoke. These
flames can take hours before they turn into a large fire.
Note:
If construction work is taking place in the area which causes a large amount of dust, you should
dismount the detector from the mounting plate to protect the detector. If you cannot for some reason,
cover the openings of the detector for the duration of the work, by e.g. a plastic bag.
A covered detector will not detect fire or smoke. Uncover it every day after work is finished.
Technical information
Sensor type: photoelectric cell
In accordance with standard EN 14604:2005/AC:2008
Service life: 10 years
Operating temperature and humidity: 0 °C to +40 °C, 5 % to 90 % (without condensation)
Protection rating: IP20
Acoustic signalisation: > 85 dB at a range of 3 m
Wireless module range: 20 m
Transmission frequency: 433 MHz, 10 mW e.r.p. max.
Number of paired units: max. 30
Power supply: 2× 1.5 V AA
Power consumption: < 170 µA standby mode, < 80 mA alarm mode
Wireless module consumption:
Receiver mode: < 5 mA, transmitter mode: < 10 mA
Temperature detection sensitivity: 54 °C to 70 °C
Smoke detection sensitivity: 0.122 to 0.189 dB/m
Size: 120 × 120 × 35.5 mm
Weight: 120 g
Detector Description
Front part
Main button TEST/SILENCE
LED
Loud siren
2

Publicidad

loading

Este manual también es adecuado para:

Gs558