Diagram for proper placement of a detector
MINIMUM
CEILING
BEST
NEVER
HERE
HERE
ACCEPTABLE
HERE
DIAGRAM 1
Installing the device onto a wall
Drill two holes (ø 5 mm) into the wall; the distance between the holes should be 60 mm.
Insert the attached wall plugs into the openings, place the mounting plate and attach it to the wall
with screws.
Put batteries into the detector and test its functionality, see Testing Mode.
If the detector is operational, place the rear side of the detector onto the mounting plate into the
two mounting pegs and turn in the direction of the arrows, see figure Mounting plate installation.
Mounting plate installation
1
2
1. Holes in the wall
2. Wall plugs
3. Mounting platea
4. Screws
5. Detector
50 cm
10 cm
MINIMUM
30.5 cm
MAXIMUM
SIDE
WALL
DIAGRAM 2
DEAD AIR
DO NOT INSTALL
PEAK CEILING
4
500 mm
NOT IN
THIS AREA
1000 mm
ANYWHERE IN
THIS AREA