Descargar Imprimir esta página

LG DLEX4070 Serie Manual De Propietario página 30

Ocultar thumbs Ver también para DLEX4070 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

30
INSTALLATION INSTRUCTIONS
(Duct check)
Installation test
Error Code
or
HS
or
or
If the FLOW SENSE
TM
LED is turned on, check the exhaust
system for restrictions and damage. Repair or replace the
exhaust system as needed.
NOTE
When the dryer is first installed, this test should be performed to
alert you to any existing problems with the exhaust duct in your
home. However, since the test performed during normal
operation provides more accurate information on the condition
of the exhaust duct than does the installation test, the number of
bars displayed during the two tests may not be the same.
Do not interrupt the test cycle, as this could result in the wrong
results.
Even if no bars are displayed during the test cycle, some
restrictions may still be present in the exhaust system. Refer to the
Venting the Dryer section of this manual for complete exhaust
system and venting requirements.
Your dryer features Flow Sense™, an innovative sensing system
that automatically detects blockages and restrictions in dryer
restrictions allows clothes to dry faster and reduces energy use.
(cont.)
Possible Causes
Temperature sensor failure
Humidity Sensor failure.
Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
Solutions
Turn off the dryer and call for
service.
Turn off the dryer and call for
service.
Check the power supply or the
connection of power cord to the
terminal block. Refer to the
this manual for complete instructions.
Do not increase the fuse capacity.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
Too many elbows or
transition duct
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
section of
exhaust too long
Lint buildup or
blockage
Crushed or
damaged
exhaust

Publicidad

loading

Este manual también es adecuado para:

Dlgx4071 serie