Descargar Imprimir esta página

Hilti DEG-125-P Manual De Instrucciones página 33

Ocultar thumbs Ver también para DEG-125-P:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
interrupter (RCD) with a rating of max. 30 mA
(tripping current). Use of a ground fault circuit
interrupter reduces the risk of electric shock.
e) Use of a ground fault circuit interrupter (RCD
residual current device) with a maximum tripping
current of 30 mA is recommended.
5.6.4 Work area
en
a) Ensure that the workplace is well lit.
b) Ensure that the workplace is well ventilated. Ex-
posure to dust at a poorly ventilated workplace may
result in damage to the health.
6 Before use
DANGER
Disconnect the plug from the power source before
making any adjustments, changing accessories, or
storing the tool. Such preventive safety measures
reduce the risk of starting the tool accidentally.
CAUTION
Wear gloves when fitting or removing parts, when
making adjustments or when remedying malfunc-
tions.
WARNING
Never use the power tool without the guard.
CAUTION
Before using another accessory that is recommen-
ded for the angle grinder in conjunction with the
angle grinders mentioned above, read the operat-
ing instructions for the applicable angle grinder and
observe all instructions.
6.1 Fitting the side handle
WARNING
The side handle must be fitted for all types of work.
The side handle may be screwed onto the tool on the
right or left.
6.2 Guard
CAUTION
Adjust the position of the guard to suit the require-
ments of the work being done.
CAUTION
The closed side of the guard must always face the
operator.
28
All manuals and user guides at all-guides.com
5.6.5 Personal protective equipment
The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat, ear protec-
tion, protective gloves and breathing protection while
the power tool is in use.
6.2.1 Fitting the guard or guard with cover plate 8
NOTE
The keyed locating lug on the guard ensures that only
a guard designed for use with the power tool can be
fitted. The keyed locating lug also prevents the guard
from coming into contact with the disc.
1.
2.
6.2.2 Adjusting the guard 6
1.
6.2.3 Removing the guard or guard with cover plate
1.
2.
6.2.4 Fitting and removing the front cover 9
1.
2.
6.3 Fitting and removing the disc 10 11
DANGER
Check that the speed rating printed on the grinding
disc is equal to or higher than the rated speed of the
tool.
Fit the guard onto the drive spindle collar so that the
two triangular marks on the guard and on the power
tool in alignment.
Press the guard onto the drive spindle collar; press
the guard release button and then rotate the guard
until it engages and the guard release button jumps
back to its outset position.
Press the guard release button and then rotate the
guard until it engages in the desired position.
Press the guard release button and then rotate the
guard until the triangular marks on the guard and
the power tool are in alignment.
Lift off the guard.
Press the front cover onto the standard guard, with
the closed side positioned as shown in the illustra-
tion, until it engages.
To remove the front cover, release the catch and
then pull the front cover away from the standard
guard.

Publicidad

loading

Este manual también es adecuado para:

Deg-125-dDeg-150-dDeg-150-p