Order of starting up steps
How to proceed:
1. Close the slide valve for the dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Remove the container cover.
4. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
5. Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing pump).
6. Fit the container cover.
−
The filter drum is stopped for safety reasons if the filter cover is lifted.
7. Switch on the control system and perform any necessary adjustments. (→ Operation)
8. Switch on the filter pump and UVC clarifier (if applicable).
Ensure that the water is returned to the pond via the return pipe.
−
9. Check all pipes, hoses and their connections for leaks.
−
Expansion seals may leak initially until they have fully expanded on contact with water.
When using filter starter, medicines or pond water treatments, leave the UVC clarifying unit switched off
for at least 36 hours so as not to impair their efficacy.