ELECTRICAL CONNECTION
(only intended for qualiied personnel)
Disconnect the equipment from electrical mains power supply before carry-
ing out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualiied personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.
Before connecting the hood to the electrical mains power supply, check that:
• voltage supply corresponds with what is reported on the data plate located inside the
hood;
• the electrical system is compliant and can withstand the load (see the technical specii-
cations located inside the hood);
• the power supply plug and cable do not come into contact with temperatures exceed-
ing 70 °C;
• the power supply system is efectively and properly connected to earth in compliance
with regulations in force;
• the socket used to connect the hood is within reach.
In case of:
• devices itted with cables without a plugн the type of plug to use is a ''standardised'' oneв
The wires must be connected as follows: yellow-green for earthing, blue for neutral and
brown for the phase. The plug must be connected to an adequate safety socket.
• ixed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The yellow/green earth cable must not be cut of by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations..
FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are conveyed outside through
the exhaust pipe.
To this end, the hood outlet itting must be connected via a pipe, to an
external output.
The outlet pipe must have:
• a diameter not less than that of the hood ittingв
• a slight slope downwards (drop) in the horizontal sections to prevent condensation from
lowing back into the motor.
• the minimum required number of bendsв
• the minimum required length to avoid vibrations and reduce the suction performance of
the hood.
You are required to insulate the pipes if it passes through cold environments.
In the presence of motors with 800m
external air lowing back.
Deviation for Germany:
when the kitchen hood is used at the same time as appliances that are powered by energy other
than electricity, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar).
HOOD wITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through the charcoal ilters to be puriied
and recycled in the environment.
Ensure that the active carbon ilters are assembled onto the hood, if
not, install them as indicated in the assembly instructions.
In this version the check valve must not be assembled: remove it if it is on the air
outlet itting of the motor.
ASSEMBLY INSTRUCTIONS
only intended for qualiied personnel
The hood can be installed in various conigurations.
The generic assembly steps apply to all installations; for each case, follow
the speciic steps provided for the required installation.
3
/h or higher, a check valve is present to prevent
OPERATION
wHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to convey fumes and va-
pours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours.
By means of the Timer function, it is possible to set hood auto switch-of after 15 minutes
of operation.
wHICH SPEED IS TO BE SELECTED?
1st speed: maintains the air clean with low electricity consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
wHEN SHOULD THE FILTERS BE wASHED OR REPLACED?
The metal ilters must be cleaned every 30 hours of operation.
The active carbon ilters must be replaced every 3-4 months, depending on the use of the hood.
For further details see chap.''MAINTENANCE'' .
TOUCH PUSHBUTTON PANEL
ON/OFF (Blue led steady on)
Motor on/of and Speed 1
ON/OFF (blue led lashing)
If pressed for more than 3 seconds, it activates the 24h cycle (1h ON -> 3h
OFF -> 1h ON)
the function deactivates if:
- The motor turns of (key
- After 24h
Speed 2 activation
Speed 3 activation
800
m
3
/h
Speed 4 is only active for a few minutes, then speed 3 activates.
Light on/of
TIMER (red LED lashing)
Auto switch-of after 15 min.
The function deactivates (red LED of ) if:
- The motor turns of (key
- The speed is changed.
FILTER ALARM (red LED steady on with (
Anti-grease ilter maintenance after approximately 30 hours of operation.
Press the meter for 3 seconds to reset.
19
800
m
3
/h
)
).
) of )