Risk of damage to pump or other equipment.
• Do not use this pump for pumping sea water, beverages, acids, chemical solutions, or any other liquid that pro-
motes corrosion as this can result in damage to the pump.
• Do not run pump dry. For optimal cooling and to prolong the motor life, the liquid level being pumped should nor-
mally be above the top of the pump housing.
• This pump is not suitable for pond applications.
INSTALLATION
Typical Installation
1
Pump
2
Basin Cover
3
Vent
4
Power Cord Grommet
5
Discharge
6
Pump Power Cord
7
Outlet
8
Gate Valve
9
Check Valve
10 Union
11 Gas Tight Basin
12 Air Bleed Hole
13 ON Level
14 OFF Level
15 Basin Inlet
5
4
3
2
1
INSTALLATION
Typical Installation
7
6
10
15
11
12
13
14
8
9
3