Descargar Imprimir esta página

Little Giant 15EC-CIA-SFS Manual Del Propietário página 5

Bomba de foso

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Connections
Risk of severe injury or death by electrical shock.
• Always disconnect the electrical power before touching the pump, discharge or electrical plug when water is
present in the area.
• Do not use the power cord for lifting the pump.
• Be certain that this pump is connected to a circuit equipped with a ground fault circuit interrupter (GFCI) device if
required by code.
Connect the power cord to a constant source of power
matching the pump nameplate voltage.
• Connect the pump to its own circuit, with no
other electric receptacles or equipment in the
circuit.
NOTE: Do not connect to a fan or any device that
runs intermittently.
• The fuses or circuit breaker should use a 15 A
breaker.
IMPORTANT: If the power cord is damaged, the
whole unit must be replaced
OPERATION TESTING
Risk of damage to pump or other equipment.
• If pump is run dry, it may damage pump and will void the warranty.
• Do not let the unit freeze. Freezing may cause cracking or distortion that may destroy the unit.
NOTE: If the unit is going to be idle for a period of time, refer to
page
6.
Testing Automatic Pump Operation
The automatic pumps are equipped with an integral float-operated mechanical switch which will turn
the pump on when water level reaches the levels shown in
1. Remove the rubber plug on the basin cover in order to observe switch operation.
2. Plug the power cord into a grounded receptacle with voltage indicated on the pump nameplate.
3. Be sure the gate valve in the discharge line is open.
4. Run water into the basin until the pump is activated.
5. Make sure the pump and its float switch are functioning as intended.
• Confirm that no potential obstructions exist that could inhibit switch operation.
• Verify the ON/OFF levels are within specification.
OPERATION TESTING
Electrical Connections
BLUE
BLK
Switch
BLK
WHITE
115 V Plug
"Cleaning Impeller and Volute" on
"Specifications" on page
RED
WHITE
Cap
RED
GREEN
1.
5

Publicidad

loading