3.4 SELECTING A LOCATION
If the system has been tilted more than 45°, leave it upright for at least 12 hours before
commissioning.
of free space around the unit for good air circulation.
other objects that could block the air inlet and outlet. Ensure that the air inlet
and outlet remain free of obstacles.
the following:
Warning
The system must be installed in rooms that meet the specified room size; see the technical data
regarding this matter.
The system may not be installed in a place where flammable gas could escape.
3.5 CONNECTING THE EXHAUST AIR HOSE
The air conditioner must be vented to the outside so that the exhaust air coming from the unit
and containing waste heat and moisture can escape from the room. Do not replace or lengthen
the exhaust hose, as this may damage the unit.
Step 1: Connect the hose connector to one end of the exhaust hose.
Step 2: Connect the adapter for the window kit to the other end of the exhaust air hose.
Step 3: Adjust the adjustable window kit by the length of your window. To do so, insert the
hammer-head bolt into the window kit's groove, attach the second window kit element with the
nut and washer through the inserted hole.
Connect the exhaust air hose to the window kit.
Place the unit on a solid, horizontal surface, leaving at least 50 cm
Do not place the unit in the immediate vicinity of walls, curtains or
The unit must never be installed where it could be endangered by
Heat sources such as radiators, heat storage units, stoves or other
products that generate heat
Direct sunlight
Mechanical vibrations or shocks
Excessive dust
Insufficient ventilation, e.g. in a cupboard or bookcase
Uneven surface
28