2.- TECHNICAL INSTALLATION INSTRUCTIONS FOR
THE INSTALLER
The installation of the grills, must be carried out only and exclusively by
authorized personnel and based on current regulations, according to the
regulations of the country of destination.

2.1.- PREVIOUS INSTRUCTIONS

- These instructions are only valid if the country symbol appears on the
device.
- The roaster should be installed on a counter and at a minimum distance
from the side walls of 200 mm taking into account that both the counter
and the walls must be non-combustible materials and able to withstand
a temperature increase of 65ºC.
- It will be verified that all the elements that make up the device are per-
fectly located and that due to the transport they have not suffered any
misalignments.

2.2.- INSTALLATION PLACE

- It will be a completely clean place.
- It will be conveniently ventilated both in the air inlet and in the evacua-
tion of the products of combustion in accordance with the regulations of
each country, placing the appliance under an extraction hood of at least
500 m 3 / h .; Taking into account that if there were more gas appliances
installed, the amount of air required is 10 m 3 / h. per kW installed.
- It will be placed at a minimum distance from the walls as indicated in
the plan.
- The grill will only be installed in a place with sufficient ventilation to pre-
vent the formation of inadmissible concentrations of substances harmful
to health.
- The grills do not require a special fixation, they will be placed directly
on the surface, checking that it is level and stabilized.
- The grills of 6 and 8 swords are equipped with wheels to move them
better.