MODEL: TP3 COND 370 (OIL)
Trademark: FERROLI
Condensing boiler: YES
Low-temperature boiler (**): NO
B1 Boiler: NO
Combination heater: NO
Cogeneration space heater: NO
Item
Rated heat output
Seasonal space heating energy efficiency
Useful heat out put
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful efficiency at rated heat output and high-temperature regime (*)
Useful efficiency at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet..
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
MODEL: TP3 COND 370 (GAS)
Trademark: FERROLI
Condensing boiler: YES
Low-temperature boiler (**): NO
B1 Boiler: NO
Combination heater: NO
Cogeneration space heater: NO
Item
Rated heat output
Seasonal space heating energy efficiency
Useful heat out put
Useful heat output at rated heat output and high-temperature regime (*)
Useful heat output at 30% of rated heat output and low-temperature regime (**)
Useful efficiency
Useful efficiency at rated heat output and high-temperature regime (*)
Useful efficiency at 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level
Emissions of nitrogen oxides
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet..
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature (at heater inlet).
58
EN
ErP product fiche
ErP product fiche
cod. 30902850 - Rev 06 - 04-2022
TP3 COND
Symbol
Unit
Pn
kW
ƞ
%
s
P4
kW
P1
kW
η
%
4
η
%
1
elmax
kW
elmin
kW
PSB
kW
Pstby
kW
Pign
kW
QHE
GJ
LWA
dB
NOx
mg/kWh
Symbol
Unit
Pn
kW
ƞ
%
s
P4
kW
P1
kW
η
%
4
η
%
1
elmax
kW
elmin
kW
PSB
kW
Pstby
kW
Pign
kW
QHE
GJ
LWA
dB
NOx
mg/kWh
Value
339
93
338,6
108,9
90,9
97,9
0,760
0,190
0,003
1,690
0,000
1047
78
123
Value
339
92
338,6
112,0
87,4
96,8
0,760
0,190
0,003
1,690
0,000
1064
78
64