Descargar Imprimir esta página

WAGNER 0502081 Manual De Usuario página 11

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
conditions exist. Never repair a paint hose. Replace it with another grounded high-
pressure hose.
• Pulling the trigger causes a recoil force to the hand that is holding the spray gun.
The recoil force of the spray gun is particularly powerful when the tip has been removed
and a high pressure has been set on the airless high-pressure pump. Therefore, when
cleaning without tip set the pressure control valve to the lowest pressure.
• Use only manufacturer authorized parts. User assumes all risks and liabilities when using
parts that do not meet the minimum specifications and safety devices of the spray gun
manufacturer.
EXPLOSION PROTECTION IDENTIFICATION
X marking:
The spray gun corresponds with Ex II 2G X and is, in accordance with Directive 94/9/EEC
(Atex 100a), suitable for use in explosion-hazardous areas—as of type Zone 1. Under
certain circumstances, the unit itself may cause the Zone 1 condition to be in effect.
Any static-electricity discharge from the spray gun is to be diverted to the grounded high-
pressure pump via the conductive high-pressure hose as stipulated.
The maximum surface temperature corresponds to the permissible material temperature.
This and the permissible ambient temperature can be found in the Technical Data.
To avoid the generation of machine sparks, prevent impact stresses and any work on the unit
with tools in the explosion-hazardous area.
Residual risks
Residual risks are risks, which cannot be excluded, even when equipment is used for the
intended purpose.
In such cases the applicable areas of the actual residual risks will be pointed out using warning
and/or prohibition signs.
Risk
Source / Cause
Injection
Atomized, high
injury
pressure stream of
fluid
Explosion or
Static electricity or
fire
sparks
Hazardous
Hazardous vapors
vapors
from spray material
Technical Data
Max. operating pressure
Material inlet thread size
Diffuser thread size
Wetted parts material
Operating temperature range
Maximum material temperature
Maximum sound output
Weight
* Measurement location: 0.5 m away from the coating surface, 0.5 m behind the spray gun,
spray pressure 12 MPa, tip size 0.021
AG-14
Impact
Preventative measures
Severe
NEVER aim the gun at
injury or
any part of the body
amputation
Severe
Use well ventilated area
injury
Ground the spray gun
Severe
Use well ventilated area
injury
Use mask
27 MPa (3900 PSI)
M16 x 1.5 (NPSM 1/4")
7/8 - 14 UN-2A
High-grade stainless steel, urethane, polyethylene,
nylon, hard metal
5ºC to 40ºC (40ºF to 104ºF)
43ºC (109ºF)
81 dB(A)*
590 g (1,3 lb.)
Can occur
during:
Setup,
Operation
Operation
Operation
11/16 - 16 UN-2A
GB
11

Publicidad

loading

Este manual también es adecuado para:

Ag-140502119050216605021670502168