Descargar Imprimir esta página

Chauvet Professional ROGUE R1E SPOT Guía De Referencia Rápida página 3

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
Power Linking
It is possible to power link Rogue R1E Spot products. See the table below for the current draw at each voltage and
frequency:
Current Draw
Never exceed 12 A on a single circuit. Power-linking cables can be purchased separately.
Mounting
Before mounting this product, read the
mounting clamps are capable of supporting the weight of the product. For the Chauvet line of mounting clamps, go to
http://trusst.com/productcategory/truss-clamps.
Mounting Diagram
Mounting clamp
Control Panel Description
Button
Function
<MENU> Exits from the current menu or function
<ENTER> Enables the currently displayed menu or sets the currently selected value into the selected function
<UP>
Navigates upwards through the menu list or increases the numeric value when in a function
<DOWN> Navigates downwards through the menu list or decreases the numeric value when in a function
Rogue R1E Spot QRG Rev. 1
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
100 V, 60 Hz
120 V, 60 Hz
3.17 A
2.63 A
Safety
Notes. Use at least two mounting points per product. Make sure the
Omega
bracket (2x)
Wire (Europe)
Brown
Blue
Green/Yellow
208 V, 60 Hz
230 V, 50 Hz
1.50 A
1.36 A
Safety cable
EN
Screw Color
Yellow/Brass
Silver
Green
240 V, 50 Hz
1.32 A
2

Publicidad

loading