22
Technical data
Built-in EMC, ACS55-01E-
No EMC, ACS55-01N-
Motor continuous output power
Frame size (no EMC)
Frame size (EMC)
Nominal ratings
Input voltage U
1
Continuous output current I
Max. output current I
2max
Output voltage U
2
Input current I
1
Switching frequency
Protection limits
Overcurrent (peak)
Overtemperature
Maximum wire sizes
Power terminals
Control terminals
Power losses
Line fuse size**
IEC, type IEC269 gG
UL, types CC and T
* Allowed for 1 minute.
** Recommended values. Do not use ultra rapid or low peak fuses. Follow local rules.
www.barghmaher.org
kW
hp
V
A
2
*
A
V
A
kHz
A
mm2
mm2
W
A
A
230 V
01A4-2
02A2-2
04A3-2
01A4-2
02A2-2
04A3-2
0.18
0.37
0.75
1/4
1/2
1
A
A
B
A
A
B
200-240 (+10/-15%)
1.4
2.2
4.3
2.1
3.3
6.5
0-U
, 3-phase
1
4.4
6.9
10.8
4.4
6.9
13.5
95°C / 203°F (heat sink)
2.5 (AWG 14)
21
32
51
10
16
16
10
15
20
ac.maher.co.ir
07A6-2
09A8-2
01A4-1
07A6-2
09A8-2
01A4-1
1.5
2.2
0.18
2
3
C
C
D
D
110-120 (+10/-15%)
7.6
9.8
11.4
14.7
0-2xU
18.2
22.0
5 (max. 16)
23.9
30.9
4 (AWG 12)
1.5 (AWG 16)
74
103
25
32
25
30
EN
115 V
02A2-1
02A2-1
0.37
1/4
1/2
A
A
A
A
1.4
2.2
2.1
3.3
, 3-phase
1
6.4
9.5
4.4
6.9
2.5 (AWG 14)
24
35
10
16
10
15