Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need three 230 V/60 W E-27 lamps.
During the operation, the lamp reaches temperatures of up to 200° C.
Procedure:
Step 1: Remove the old lamp from the lamp-socket.
Step 2: Put the new 230 V/60 W E-27 lamp into the socket.
Rigging
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Install the device on a plane ground.
This device features a protective insulation.
In general, lighting effects should not be connected to dimming-packs.
OPERATION
Connect the effect to the mains. With the ON/OFF-switch, you can switch the device on and off. The chaser-
speed can be adjusted via the Speed-control. The speed is also sound-controlled. You can adjust the
microphone-sensitivity via the Music-control.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
Do not operate this device with opened service lid!
DANGER OF FIRE!
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!