5. Set-up directions
1. Install the probe with the cable pointing upwards at low water level in the aquarium or filter.
2. Always plug in the power supply first, then connect the pump.
3. The system will automatically add water to the high level sensing point.
4. Let the water level below the low level sensing point to see if the system will automatically top up the water.
Notice
If you quickly lower the water level or pick up the probe during the test, residual water droplets may stay on
the probe. As long as the probe will be cleaned, it will return to normal. The surface of the probe and the
protective box have to be cleaned regularly as soiling will lead to incorrect filling.
6. Initialization
Because the system will calculate the appropriate amount of water according to the size of the aquarium and
generate the protection time when the aquarium is replaced, the initialization operation should be carried out
according to the above steps, otherwise errors may occur.
The sensor memorizes during the first startup how long it took for refilling. If, afterwards, the refill
time becomes significantly longer than the first time, the sensor stops so that there are no large fluctuations in
density or a larger storage container is pumped completely into the aquarium or filter tank. If there are constant
strong water level fluctuations in the chamber with the sensor, either because you fill the refill container too
rarely and then there are missing large quantities or because there are greater fluctuations in the overflow, then
you have to consider this at the initialization. Mount the sensor at the desired water level, the actual water level
should be at the lowest point.
For initialization, connect the power supply to the sensor first and then plug in the pump. The order
is very important. The initialization can be changed at any time by re-executing the process. During the
initialization process, the pump is working continuously, afterwards in intervals. The period of intervals depends
on the water level during initialization.
7. Failures
In case of failures and operational errors such as lack of water in the reservoir, too much water supply, the
system will stop and the alarm is indicated by a red flashing light. Disconnect the power from the system
and then reconnect the power to the unit which restarts the system. Now, the system can resume normal
operation. You can also perform a new initialization with adjusted water levels.
8. Warranty conditions
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period,
we will repair the product for free by installing new or renewed parts. This warranty only covers material and
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. In case of
a fault with the unit during or after the warranty period, please contact your dealer. All further steps
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to
us via specialist dealers cannot be processed. AB Aqua Medic is not liable for consequential damages
resulting from the use of any of our products.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
- Technical changes reserved – 08/2019
5

Publicidad

loading