Descargar Imprimir esta página

Dometic eStore 9102900224 Instrucciones De Montaje Y De Uso página 20

Ocultar thumbs Ver también para eStore 9102900224:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
Using eStore
10.1
Charging eStore
A
NOTICE!
eStore can be charged with chargers like Dometic eCore
or Waeco PerfectCharge MCA series (with LIN / CIB connection).
Use of third party charger is permitted if the following require-
ments are met:
 1. end of charge voltage between 13.8 and 14.0 V
 2. maximum output 40 A (30 A recommend) per installed
eStore
I
NOTE
Please also refer to the manual of the charger.
10.2
Changing the fuse
I
NOTE
Use a maximum 250 A fuse with 50.8 mm hole center distance.
Proceed as follows to replace the fuse:
➤ Open the cover of the positive pole (see chapter "Opening the cover of the
pole" on page 15) .
➤ Remove the nuts and washers from the fuse (fig. 0 1, page 6).
➤ Replace the fuse (fig. 0 2, page 6).
➤ Fix the new fuse with the nuts and washers (fig. 0 1, page 6). Tighten
the nuts between 13 and 15 Nm.
➤ Close the cover of the positive pole (see chapter "Closing the cover of the
pole" on page 15).
10.3
Storing eStore
I
NOTE
 Store eStore at or near room temperature.
 Avoid storage in permanent high temperatures. This shortens
the service life.
 Recharge eStore every 3 months.
20
eStore
EN

Publicidad

loading