possIble fIxIng poInts on a flat roof
notes: Each adjustable support 076226x0 for a flat roof must be anchored against slipping and overturning, due to the wind, with at least
two diameter 12 screws (chosen as required): directly on the roof structure, making sure to seal the holes to prevent water from entering,
or on a substructure arranged by the customer.
Example of substructure: cement plates, iron/cast iron plates, steel girders, concrete plates with the addition of anchorage, etc.
Attention: The substructure, to be provided by the customer, must be able to absorb the wind forces on the collectors and be fixed so as
not to damage the roof.
NOTE: In case of installation in special situations, a previous static/structural study is advisable. To make the fixing system more stable,
it is possible to increase the number of support kits 076226X0.
= RECOMMENDED FIXING POINTS on all triangles IN NORMAL LOAD CONDITIONS
= RECOMMENDED FIXING POINTS IN HIGH LOAD CONDITIONS