TIMER mode:
In this mode, the room temperature is maintained
at the COMFORT or ECONOMIC temperature
depending on the programmes set for the diffe-
rent time slots of the day (P1, P2 or P3).
To activate it, follow the following steps:
Press the "Mode" button
icon appears on the display.
Press the TIMER button
pre-set factory programmes (
the user-configurable programme (
For P3 configurable programming, refer to section
"4. PROGRAMMING" in the manual.
The pre-established P1 and P2 programmes are:
1 Comfort mode
2 Night mode
3 Days 1 until 5 (Monday to Friday)
4 Days 6 until 7 (Saturday and Sunday)
TURBO/BOOST mode:
This mode can be used when you want to heat
the room more quickly.
To activate it, follow the following steps:
Press the "Mode" button
icon appears on the display.
Pressing the buttons
select the duration of the TURBO/BOOST pe-
riod from 5 to 120 minutes. When this function
is activated, the radiator operates at maximum
power, controlling that the room temperature
does not exceed 32°C. When the programmed
time (indicated by a countdown on the display)
expires, the radiator returns to the previously
set mode.
repeatedly until the
to select one of the
and
).
repeatedly until the
and
, it is possible to
ECONOMY mode 17⁰C: When this mode
is activated, the radiator operates at a preset
temperature of 17°C, which cannot be changed.
This function allows for lower consumption
when, for example, the room or house is empty
for an indefinite period of time.
To select this mode, press the "Mode" button
repeatedly until the
display.
) or
OTHER FUNCTIONS AND ICONS
OPEN WINDOW DETECTION:
The radiator is able to detect if a window has
been opened by a sudden drop in temperature
(5 °C within a maximum of 30 minutes). If this
happens, the device switches off for 30 minutes
and then resumes operation in the previously
set mode if it detects continuous temperature
increases of one degree (e.g. because the win-
dow has been closed). If this is not the case, the
device will remain switched off for an additional
30 minutes.
When the open window detection is activated,
the corresponding symbol
display (except in off/stand-by mode). When
deactivated, the symbol disappears.
To activate this function, see section "4. PRO-
GRAMMING".
CHILD SAFETY:
When this function is activated, the temperature
of the front of the radiator is reduced so that it
is safe in the presence of children. In addition,
this function allows the same radiator to be
used in smaller rooms than the one in which it is
installed without significant changes in the room
temperature.
When this function is activated, the power level
at which the radiator operates is set by the user
(40% - 50% - 60%).
To activate this function, see section "4. PRO-
GRAMMING"..
ASC (ADAPTIVE TEMPERATURE CON-
TROL):
When this function is activated, the appliance
switches on before the time set in the program-
ming (maximum 2 hours before) to ensure that
the room will be at the programmed temperature
at the set time.
icon appears on the
will flash on the