Operating Modes
Rotational Mode
For best performance when using the remote/re-
ceiver, use 600 RPM. Different RPMs can be selected
by pressing the Rotational Speed Button on the laser
(1200, 300, and 600).
Sweep Mode
When using sweep mode, the laser beam oscillates
within a limited range. The visibility of the laser beam
is enhanced compared to rotational mode. Different
sweep angles can be selected by pressing the Sweep
button on the laser (0°,10°, 45°, and 90°).
Plumb Point Mode
The laser will default to Plumb Point Mode when
placed in the vertical orientation. Use the plumb
dot projected on the working surface to orient and
set up the lasers before entering the Rotational or
Sweep Mode.
Auto-Leveling Mode
When the laser initially turns on, the laser will au-
tomatically start to self-level. The Leveling Mode
Indicator LED will begin flashing green.
• During the leveling process, the Bump Alarm will
not be active. When the laser is leveled, the Level-
ing Mode Indicator LED will be solid green and
the laser head will start to rotate. The laser will be
ready for use.
• If the leveling process fails either by the one-minute
timer or out of leveling range, the Leveling Mode
Indicator LED flashes red, the laser diode turns off
and stops rotating, and an audible tone will sound.
NOTE: If the laser fails to level, ensure the laser
is on a stable surface. This error occurs when the
working surface causes the laser to be outside the
leveling range. After, try pressing the Leveling Mode
Button or power cycling the laser to trigger a relevel.
If the problem persists, please contact an authorized
MILWAUKEE service facility for support.
Complete Manual Mode
The laser will default to Auto-Leveling Mode. Com-
plete Manual Mode can be used to deactivate Auto-
Leveling and allow the user to manually position
the laser plane. Ensure the laser has self-leveled
(Leveling Mode Indicator LED is solid green).
1. Press the Leveling Mode button.
2. The Leveling Mode Indicator LED will turn solid red
and remains on (the laser will no longer attempt
to Auto-Level).
3. To turn OFF, press the Leveling Mode button
again. The Leveling Mode Indicator LED will flash
green and become solid once the level is achieved.
Entering/exiting Complete Manual Mode will re-
initialize the Bump Alarm to allow for further setup.
Manual Slope Mode
The laser plane can be manually sloped using a
paired remote/receiver. When in Manual Slope Mode,
the Leveling Mode Indicator LED will illuminate yel-
low. The laser will auto-level in one axis while sloping
in the other.
• Start the operation using the remote/receiver. See
the remote/receiver manual.
• To Exit Manual Mode from the laser, press the Level-
ing Mode button. The laser will enter Auto-Leveling
Mode and begin to self-level. The Leveling Mode
Indicator LED will turn solid green when leveling
is achieved.
Bump Alarm
Due to the laser's high leveling accuracy, the laser
is very sensitive to knocks, vibrations, and changes
in position. The Bump Alarm will be triggered if the
laser is moved from its initial location.
• The Bump Alarm will only be off while the laser
establishes a new position.
• Once the Leveling Mode is established, the Leveling
Mode Indicator LED becomes solid (green, yellow,
or red), and the Bump Alarm Indicator LED will
begin to flash white. During this time, disturbances
will not trigger an alarm but will restart the initializa-
tion timer. After 30 seconds with no adjustments or
inputs, the Bump Alarm Indicator LED will become
solid white and the Bump Alarm will be active. Any
bumps above the sensitivity limits will trigger the
alarm. The laser diode will turn off, the head will
stop rotating, the Bump Alarm Indicator LED will
flash white, and the Leveling Mode Indicator LED
will flash red. The laser will play an audible alarm.
NOTE: The laser will default to High Sensitivity. Set
up the laser on a flat and stable surface to avoid in-
terruptions in operation. If the Bump Alarm becomes
overly sensitive for environmental conditions, the
setting can be viewed and changed using a paired
remote/receiver.
Clearing the Bump Alarm (Option 1):
• Press the Leveling Mode button, and the laser will
run Auto-Leveling sequence. Additional setup may
be needed if the laser was moved from its previous
position.
Clearing the Bump Alarm (Option 2):
• If the user suspects the laser has not been signifi-
cantly disturbed, press the Rotational Speed button
to clear the warning or clear with the OK button on
paired remote/receiver and the laser head will start
spinning in its current position. Inspect the laser
plane to determine if it has been moved to determine
if re-set up is needed.
NOTE: The laser will recall previous settings that
were applied.
Sleep Mode
To conserve battery, the laser can be put into Sleep
Mode from a paired remote/receiver. In this mode,
the laser head will stop spinning, the laser diode and
the Leveling Mode Indicator LED will turn off. The
Pairing Indicator LED and Bump Alarm Indicator LED
will continue to display the current setting.
1. To turn ON Sleep Mode, select the Sleep icon from
the main menu on the remote/receiver.
2. Press the OK button to send the laser to "sleep"
mode.
3. To turn OFF Sleep Mode, press any button on the
laser or follow instructions to "wake" on a paired
remote/receiver. The laser will function with the
same settings and modes as when it entered
Sleep Mode.
Temperature Alarm
The laser monitors temperatures when the tool is
active or in Sleep Mode. If the minimum or maximum
operating temperature limits are exceeded, the
Leveling Mode Indicator LED will flash, alternating
between red>green>red; in this pattern, laser diode
will turn off, and the head will stop rotating. The laser
will automatically turn off after 5 minutes of this alarm.
6