Milwaukee 3702-20 Manual Del Operador página 8

Nivel de láser giratorio interior verde m18

Publicidad

Idiomas disponibles

Idiomas disponibles

II II
d d
I I
6. Repeat the steps above in other axis.
Leveling Accuracy for
Vertical Orientation
Ensure the area is clear of obstructions before do-
ing this operation. Attach a Plumb Bob to the ceiling
near a wall. The Plumb Bob should be a minimum
of 30' in length.
1. Ensure the work area is on a flat, clean surface.
2. Place the laser in the correct vertical orientation
with the keypad facing up and parallel to the
ground. If possible, elevate off the ground. Be
sure the setup is stable before proceeding to the
next step.
3. Turn ON the laser by pressing the power button,
and wait for the self-leveling sequence to finish.
The Leveling LED Indicator will be solid green.
4. Press the Rotational Speed button to start the laser
head rotation. Manually turn the tool to align the
laser, so it crosses the Plumb Bob line at least 30'
above the ground.
5. Measure the distance between the Plumb Bob
string and the laser at the base of the wall. This
distance represents the laser's actual deviation
from plumb. The maximum deviation allowed
should be 3/64" over 30' (or 1/8" at 100').
30'
30'
180°
180°
d d
Plumb Dot Accuracy
A free measuring distance of approximately 15'
between the floor and ceiling on a firm surface is
required. It's suggested to elevate the tool off the
ground for this operation.
1. Place the tool within 1' of the floor.
2. Turn ON the tool by pressing the power button.
3. Mark the center of the plumb point on the ceiling
(point I).
4. Rotate the tool 180° being as careful as possible
to keep the center of the laser in the exact same
location.
5. Mark the center of the top plumb point on the
ceiling (point II).
6. The distance between (points I and II) on the
ceiling is the deviation (d) of the tool. This dis-
tance should not exceed 3/64" (max.) at 30'.
For the measuring distance of 2 x 15' = 30', the
maximum allowable deviation (d) is: 30' x ±3/64"
÷ 30' = ±3/64".
NOTE: If any of the above accuracies are out of spec,
return the laser to nearest authorized MILWAUKEE
service center for recalibration.
MAINTENANCE
To reduce the risk of injury, always
WARNING
unplug the charger and remove the
battery pack from the charger or tool before
performing any maintenance. Never disassemble
the battery pack, charger, or tool, except as pro-
vided in these instructions. Contact a MILWAUKEE
service facility for all other repairs.
Maintain Rotary Laser
Maintain tools. If damaged, have the tool repaired
by an authorized MILWAUKEE service center before
use. Accidents may be caused by poorly maintained
tools.
8
I I
II II
15'
15'
d
d
I I
II II

Publicidad

loading