HomeWorks
®
Specifications
Model Numbers
Power
Typical Power
Consumption
Regulatory Approvals
Environment
Heat Generated
Cooling Method
Power Failure Memory
Internal Timeclock
Miswire Protection
Low-Voltage Link
Wire Type
Low-Voltage Power
Wire Type
Communications
Link Capacities
ESD Protection
Surge Protection
Mounting
Dimensions
Connections
Warranty
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
|
2
Lutron
®
product specifications
QS Processor
HQP6-2
Processor (P): 24 V- 250 mA
Links (L1 / L2): 24 V- 2 A per link
5 W; 8 Power Draw Units (PDUs)
Test conditions: Two Ethernet links connected, both device links in use
UL, cUL, CE, CTICK
Indoor use only. 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity,
non-condensing
17 BTU/hr — typical
(24 BTU/hr with 2 links at 2 A each output)
Passive Cooling
System data stored in non-volatile memory. Timeclock retention for
10 years
±1 minute per year
All terminal block inputs are over-voltage and miswire protected against wire
reversals and shorts.
Two pair — one pair 18 AWG (0.75 mm
(0.34 to 0.75 mm
18 AWG (0.75 mm
Ethernet, RS485 (QS, RF, Power Panel)
HomeWorks
/ HomeWorks
®
HomeWorks
 QS Wired Device Link
®
HomeWorks
 QS RF Link
®
Meets or exceeds the IEC 61000-4-2 standard
Meets or exceeds ANSI/IEEE C62.41 standard
Mounts in HQ-LV21, L-LV14, L-LV21, or PNL-8 enclosure
With terminal blocks (as shown): 4.27 in (108 mm) x 6.0 in (152 mm)
Without terminal blocks: 4.27 in (108 mm) x 5.26 in (134 mm)
Two 5-pin removable terminal blocks* for Links 1 and 2.
One 5-pin removable terminal block* for Power Input.
Two RJ 45 standard Ethernet connections.
*Each terminal will accept up to two 18 AWG (0.75 mm
http://www.lutron.com/TechnicalDocumentLibrary/HomeWorks_Warranty.pdf
http://www.lutron.com/TechnicalDocumentLibrary/ HomeWorks_Intl_Warranty.pdf
2
) twisted shielded — IEC PELV / NEC
2
)
2
 QS Power Panels
®
24/7 Technical Support—800.523.9466
369376b
), one pair 18 to 22 AWG
Class 2 cable
®
16 addresses / 256 zones
100 devices / 500 zones
100 devices / 100 zones
) wires.
2
05.23.12

Publicidad