Except for the COR F-1000 N and F-1500 N, that can only be used as an Air Curtain
with fresh air, the rest of models on this range have the option of working either with
fresh or warm air.
We advise you to check that the unit is in perfect condition when unpacking it, as any
manufacturing or quality defect is covered by the S&P guarantee.
IMPORTANT: SAFETY GUIDELINES
The appliance must not be right above or below a socket.
Do not cover the unit with clothes or objects that may obstruct the airflow and cause
overheating.
While in operation, the connection cable must not be in front of the air outlet.
If it is installed in the bathroom, it must be placed so that the switches or other devices
of command cannot be touched for a person that be in the bathtub or shower.
There must not be any inflammable objects at less than 50 cm from the unit (such as
window curtains, etc.)
Keep the inlet and outlet grilles clean. When cleaning them, disconnect the unit from the
main supply.
Do not manipulate the unit with wet hands.
The installation work must be carried out by an electrician.
IMPORTANT:
THIS APPLIANCE MUST BE EARTHED.
The means of disconnection from the mains supply must have an opening distance of at
least 3 mm in all poles.
To operate the unit as an Air Curtain, the maximum distance to the floor must not be greater
than 3 m.
The minimum distance between the Air Curtain and the floor must be 1,8 m.
INSTALLATION
The unit must be fixed to a convenient surface, and the minimum distances shown on
Fig. 1 must be kept.
To install the unit, proceed as follows:
If the spiral nuts already placed in the device are used, there must be marked the
centers of the screws (M-8) according to the table of Fig.2 (a) and Fig.2 (b). If the hang-
ing fixation is used, the centers must be marked according to the table of Fig.3 (a) and
Fig.3 (b) and place the screws (D) and the set squares (E). Then hang the device and to
fix on the lowest part with the screw (G).
ELECTRICAL CONNECTION (Fig. 4)
The COR Air Curtains are installed appliances. When installing these air curtains, the
standards and regulations in force in your country must be followed strictly adhered to.
Within the installation an electrical isolation switch must be present, to enable the in-
staller to cut all supply lines.
Connect the unit to the mains supply, checking that the voltage and frequency are the
same as those indicated on the electrical rating plate. Use the cables with the number of
wires and
sections as indicated on the wiring diagram for every model.
The connection can be made either through the back or by the side of the units. In case
of connection by the side, the lid of the connections must be mounted through the cable
before carrying the connections.
Fix the cable with the clamp provided and mount the front cover.