Specific information for appliances with R600A refrigerant gas.
•
Thoroughly read all warnings.
•
When defrosting and cleaning the appliance, only use tools
recommended by the manufacturer.
•
Place the appliance in a room without any active ignition sources
(e.g. an open flame, switched on electric or gas appliance).
•
Do not drill into or burn the device.
•
This appliance contains 31 grams of R600A refrigerant gas
(see the information plate at the rear of the appliance).
•
R600A is a refrigerant gas that is in accordance with the European
environmental directives. Never drill into any part of the cooling
circuit.
•
If the appliance is installed, operated or stored in a room
without ventilation, the room should be designed in a way that
accumulation of refrigerant as a result of a leak is prevented. This
could lead to a fire or explosion hazard due to the ignition of the
refrigerant by an electric heating appliance, stove or other ignition
source.
•
Store the appliance in a way that mechanical failures are
prevented.
•
Persons operating or working on the cooling circuit must be
in the possession of a suitable certificate from an authorized
organization, to ensure that these persons are authorized to handle
refrigerants in a safe way in accordance with the specifications that
apply within the industry.
•
Repairs may only be performed as recommended by the
manufacturer of the appliance. Maintenance and repairs that
require assistance from other trained personnel must be performed
under the supervision of a person familiar with the use of
combustible refrigerants.
Caution, risk of rire, R600A