INSTALLATION
Installing/Replacing the lamp
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
During the operation, the lamp reaches temperatures of up to 800° C.
For the installation, you need a 240V/575W GX-9.5 lamp.
Procedure:
Step 1: Unscrew the knurled screw of the lamp housing.
Step 2: Remove the lamp housing from the device.
Step 3: If replacing the lamp, remove the old lamp from the socket.
Step 4: If the lamp base is the same as shown in figure 1, then insert the 240V/575W GX-9.5 lamp into
the lamp-socket.
Step 5: If the lamp base is the same as shown in figure 2, then first remove the retention box before
inserting the new lamp. Save the retention box for furture use.
Step 5: Replace the lamp housing onto the device and tighten the screw.
Lamp base
Figure 1
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
HPL Lamp
Retention box
Do not operate this device with opened lamp housing!
15/35
CAUTION!
Retention box
Lamp housing
,
Knurled screw
Figure 2
HPL Lamp
Lamp socket
40002500_V_1_0_2643.DOC