Descargar Imprimir esta página

Interlogix VE1120AM Instrucciones De Instalación página 5

Ocultar thumbs Ver también para VE1120AM:

Publicidad

Low voltage
PIR intruder
alarm
PIR/AM
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM
reset
Technical
fault
Continuously on
Normal blinking (1 Hz)
Fast blinking (4 Hz)
* Depends on the setting of the DIP switch SW4.
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
For UL/cUL installations
Peak-to-peak ripple
Detector start-up time
Normal current
For UL/cUL installations
Current in alarm
Maximum current
(LED on)
Mounting height
Dead zones
0.9 m (3 ft.) at minimum mounting height
1.5 m (5 ft.) at maximum mounting height
Target speed range
30 cm/s to 3 m/s
(1 ft./s to 10 ft./s)
Alarm (NC) / Tamper
80 mA, 30 VDC,
relay characteristic
Pry-off tamper (not
evaluated by UL/cUL)
AM relay characteristic
PIR Alarm time
Operating temperature
For UL/cUL installations
Dimensions (H x W x D)
125 × 55 × 60 mm
P/N 146279999-5 • REV 00.01 • ISS 29JUL11
Open
Apply correct
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Alarm
AM
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
Switch to Night
mode
Open
Do a successful
(Alarm)
walk test
VE1120
VE1120AM
PIR
PIR with AM
V2E
20 m
11 high-density mirror curtains
Yes
9 to 15 VDC (12 V nominal)
10 to 15 VDC (12 V nominal)
2 V (at 12 VDC)
25 s
60 s
6.5 mA
10 mA
0.078 W
1.2 mA
3.8 mA
11 mA
24 mA
1.8 to 3.0 m (5.9 ft.to 9.8 ft.)
20 cm/s to 3 m/s
(0.65 ft./s to 10 ft./s)
80 mA, 30 VDC
resistive
Optional
Onboard (yes)
80 mA
at 30 VDC max.
3 s
−10 to +55°C (14 to 130°F)
0 to 49°C ( 32 to 120°F )
125 × 65 × 60 mm
(4.92 x 2.16 x
(4.92 x 2.6 x 2.36 in.)
2.36 in.)
Relative humidity
Weight
IP/IK rating
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
UL/cUL
The product must be connected to a listed burglar
system compatible control unit or power supply unit,
which provides a minimum 4 hours of standby power
and has a voltage output between 10 and 15 VDC.
All wiring must be made according to National
Electrical Code, NFPA70, and CSA C22.1, Canadian
Electrical Code Part I, Safety Standards for Electrical
Installations.
Perform walk test at least one per year.
Use only a listed power-limited supply.
VE1120AM has not been evaluated by UL/cUL.
2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.
Contact information
For contact information see our Web site:
utcfireandsecurity.com.
DE: Installationsanweisungen
Einführung
Die Serie VE1120-D/VE1120AM-D besteht aus PIR/PIR-AM-
Bewegungsmeldern. Letztere verfügen über einen patentierten
Spiegel sowie Pyro- und Signalverarbeitungstechnologie.
Installationsanleitungen
Die in diesen Meldern eingesetzte Technologie dient zur
Vermeidung falscher Alarmmeldungen. Dennoch sollten Sie
potenzielle Instabilitätsfaktoren vermeiden (Abb. 1), darunter:
Direkte Sonneneinstrahlung auf den Melder
Starke auf den Melder gerichtete Zugluft
Hitzequellen innerhalb des Erfassungsbereichs
Tiere innerhalb des Erfassungsbereichs des Melders
Verdecken des Erfassungsbereichs des Melders durch
große Objekte, z. B Möbel
Objekte innerhalb von 50 cm des Melders mit
Abdeckerkennung (AM)
Montage zweier gegenüberliegender Melder in einem
Abstand von weniger als 50 cm
VE1120
VE1120AM
95% max. noncondensing
(UL/cUL Installations)
150 g
IP30 IK02
5 / 20

Publicidad

loading

Este manual también es adecuado para:

Ve1120 serie