Multiple Outlet Connection
If the user wants to implement a multi-pipe supply system, please refer to the method
shown on the drawing for connection.
Power Socket
Piping and Electrical Connection
Reference Diagram
The rated pressure of safety valve is 0.75MPa. When the pressure of the pipeline system
exceeds its rated pressure, the safety valve will automatically drain and relieve pressure,
and water flow out of the outlet is a normal phenomenon.
The drain pipe connected to the pressure relief device (safety valve) must be installed in a
continuous downward direction in a frost-free environment. (Lead the other end continuously
downward to a safe drain (such as into a floor drain) to prevent hot water from flowing out).
Notice
The blue is the water inlet, and the red is the water outlet.
If the hot water pipe is too long, it should be insulated to reduce heat loss.
When setting a power socket, determine the installation position according to the actual
length of the cable.
Test Run
① After all installation is completed, open all valves in the pipeline, then open the hot
water tap, fill the appliance with water and close the hot water tap. Check whether the
pipes are leaking. If so, reconnect the pipes.
② Unscrew the stop screw at the handle of the safety valve, pull the handle of the
safety valve, and check whether the water discharge of the safety valve is smooth
(continuous water outlet means normal).
③ After confirming normal operation, switch on the power and run the appliance acco-
rding to the operation method section. Power off and disconnect when all is well.
Ground Connection
Safety Valve
Inlet Valve
Installation
Drain Handle
Thread Screw
Safety Valve