Descargar Imprimir esta página

Generac 1539-0 Manual Del Propietário página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

Generac Portable Products 3000 PSIPressure Washer
• If the choke lever has been moved to the "Closed"
position to start the engine, gradually move it to the
"Open"
position as the engine warms up.
• Attach the nozzle extension to the spray gun. Tighten by
hand (Figure I I).
• Select the desired quick connect nozzle and insert it into
the end of the nozzle extension (see "How To Use the
Nozzles").
• Disengagethe safety latch on the spray gun.
How
to
Stop Your Pressure
Washer
• Move the throttle lever to the "Slow" position.
• Move the fuel valve to the "Off"
position.
• Wait for the engine to idle down.
• Move the engine switch to the "Off" position.
• Simply shutting off the engine will not release pressure in
the system. Squeeze trigger on the spray gun to
relieve pressure in the hose.
Flow to Use the Nozzles
_
CAUTION!
Never exchange nozzles without
lockingthe safety latch on the trigger.
The quick-connect on the nozzle extension allows you to
switch between five different nozzles. The nozzles vary the
spray pattern as shown below (Figure 12).
Follow these instructions to change nozzles:
• Engagethe safety latch on the spray gun.
•Putl back the collar on the quick-connect and pult the
current nozzle off. Store the nozzle in the space provided
on the handles storage panel.
NOTE: For a more gentle rinse, select the white 40 ° or
green 25 ° nozzle. To scour the surface, select the yellow
15° or red 0° nozzle. To apply chemical, select the black
nozzle.
•Putl back on the collar, insert the new nozzle and release
the collar. Tug on the nozzle to make sure it is securely
in place.
• For most effective cleaning, keep the spray nozzle
between B to 24 inchesaway from the cleaning surface. If
you get the spray nozzle too close, you may damage the
cleaning surface.
Low Pressure
apply
chemical
Black
25 °
High Pressure
White
Green
Yellow
Red
40 °
25°
15°
0 °
/
9

Publicidad

loading