To fasten the grinding/cutting disc, screw on the clamping
nut (9) and tighten with the two-hole spanner.
After fitting the abrasive tool, check that the abrasive
u
tool is fitted correctly and can turn freely before
switching on the power tool. Make sure that the abras-
ive tool does not brush against the protective guard or
other parts.
Flap disc
Always fit the hand guard (13) when working with the
u
flap disc.
Rubber sanding pad
Always fit the hand guard (13) when working with the
u
rubber sanding pad (14).
See the graphics page for fitting instructions.
Screw on the round nut (16) and tighten with the two-pin
spanner.
Cup brush/disc brush
Always fit the hand guard (13) when working with the
u
cup brush or disc brush.
See the graphics page for fitting instructions.
The cup brush/disc brush must be screwed onto the grinding
spindle until it rests firmly against the grinding spindle flange
at the end of the grinding spindle thread. Tighten the cup
brush/disc brush with an open-ended spanner.
Approved abrasive tools
You can use all the abrasive tools mentioned in these operat-
ing instructions.
-1
The permissible speed [min
] or the circumferential speed
[m/s] of the abrasive tools used must at least match the val-
ues given in the table.
It is therefore important to observe the permissible rota-
tional/circumferential speed on the label of the abrasive
tool.
Max. [mm]
D
b
115
6
125
6
115
125
75
30
Rotating the machine head
Pull the plug out of the socket before carrying out any
u
work on the power tool.
Bosch Power Tools
[mm]
-1
d
[min
]
[m/s]
22.2
12,000
80
22.2
12,000
80
12,000
80
12,000
80
M 14
12,000
80
without removing it from the housing, into the new posi-
tion. Screw in and retighten the four screws.
Dust/Chip Extraction
The dust from materials such as lead paint, some types of
wood, minerals and metal can be harmful to human health.
Touching or breathing in this dust can trigger allergic reac-
tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
– Use a dust extraction system that is suitable for the ma-
terial wherever possible.
– Provide good ventilation at the workplace.
– It is advisable to wear a P2 filter class breathing mask.
The regulations on the material being machined that apply in
the country of use must be observed.
Avoid dust accumulation at the workplace. Dust can
u
easily ignite.
Operation
Start-Up
Pay attention to the mains voltage. The voltage of the
u
power source must match the voltage specified on the
rating plate of the power tool. Power tools marked
with 230 V can also be operated with 220 V.
Products that are only sold in AUS and NZ: Use a resid-
u
ual current device (RCD) with a nominal residual current
of 30 mA or less.
When operating the power tool using a mobile generator that
does not have sufficient reserve capacity or an adequate
voltage control system with inrush current boost converter,
loss of performance or atypical behaviour may occur upon
switch-on.
Please check the suitability of the power generator you are
using, particularly with regard to the mains voltage and fre-
quency.
Hold the tool by the insulated gripping surfaces and
u
auxiliary handle only. The application tool could come
into contact with hidden wiring or its own cord. Con-
tact with live wires may make metal parts of the tool live,
posing a risk of electric shock.
English | 11
The machine head can be
rotated in 90° increments.
In this way, the on/off
switch can be brought into
a more favourable handling
position for particular ap-
plications, e.g. for left-
handed tool users.
Completely unscrew the
four screws. Rotate the ma-
chine head carefully,
1 609 92A 36V | (01.06.2021)