Function F6 - Assign points of discharge to the buttons of the digital diverter (not for 36 292
Button Description
Start the function menu
- Select the function by simultaneously pressing the - / + buttons.
- F6 Function select by turning the ring.
• Start F6 - Assign points of discharge to the buttons of the digital diverter.
=> Confirm by simultaneously pressing the - / + buttons.
- Press one of the digital diverter buttons 1, 2 or 3.
- Change point of discharge by turning the digital controler ring. The buttons are
factory assigned to the points of discharge 1 - 2 - 3.
By further turning the point of discharge may be closed. A maximum of two point of
discharge could be stored as closed.
- Press the next digital diverter button.
=>
Pressing the - / + buttons simultaneously saves the selection and exits the menu.
Abort the function menu by pressing and holding Start/Stopp button or after
3 minutes without triggering.
Maintenance
Inspect and clean all components and replace if necessary.
Close isolating valves. Open all occupied outlets with digital
controller/diverter. Disconnect voltage supply.
I. Change digital controller/diverter batteries, see fold-out page IV,
Fig. [23] and fold-out page III, Figs. [11] to [15].
Insert batteries with correct polarity.
II. Servo motor and thermostatic compact cartridge, see fold-out
page IV, Figs. [24] to [26].
Assemble in reverse order.
Observe the correct installation position of the thermostatic compact
cartridge, see detail Fig. [25].
1.Connect plug connector servo motor, see Fig. [24].
2.Establish voltage supply. The servo motor calibrates and the buttons of
the digital controller/diverter are now inoperative for 3 minutes. Finally
the cams must be positioned one above the other, see Fig. [26].
If cams are not positioned one above the other, disconnect voltage
supply and than reconnect again.
3.Open isolating valves and start water flow at the digital controller.
Fault
Cause
Water does not flow
• Water supply interrupted
• Plug-in connector without contact or no voltage
supply
• Solenoid valve defective
Flow rate too low
• Functional unit not adapted to local conditions
Water too cold/hot
• Functional unit not adapted to local conditions
No function
• Digital controller not ready or registered
• Digital controller/diverter out of range
• Radio interference
Segment flashes 1x white
• Obstacle in transmission path
• 1x: Batteries digital controller/diverter almost
empty
Segment flashes green
• 3x: Temperature too high
• 5x: Calibration servo motor not completed
• Software malfunction
Segment flashes 1x yellow
• Hard- or software malfunction
Segment flashes 1x red
Please pass these instructions on to the fitting user!
The right to make technical modifications is reserved!
)
, see fold-out page IV, Fig. [21].
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 6x..
Illuminated ring flashes green 1x.
Water flow starts and the segment of the selected
button flashes blue 1x.
Water flow changes to the selected point of discharge.
Water flow starts and the segment of the selected
button flashes blue 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
4.Turn the adjusting nut (C) until the water temperature reaches 38 °C,
see Figs. [22] and [24].
5.Put servo motor to thermostatic compact cartridge.
III. Non-return valve, see fold-out page IV, Fig. [27].
Assemble in reverse order.
IV. Solenoid valve, see fold-out page IV, Fig. [28].
Assemble in reverse order.
Service
In the event of problems with installation, please switch off the voltage
supply and consult a specialist installer or the GROHE Service Hotline via
email at TechnicalSupport-HQ@grohe.com.
Replacement parts
See fold-out page I (* = special accessories).
Disposal instructions
This category of device does not belong in the domestic waste,
but must be disposed of separately in accordance with the
relevant local national regulations.
Dispose of batteries in accordance with national regulations.
Remedy
- Open shut-off valves, isolating valves
- Attach plug-in connectors and connect voltage supply
- Replace solenoid valve, see section Maintenance
- Adapt functional unit to local conditions, see Function F2 - Setting
mode
- Adapt functional unit to local conditions, see Function F2 - Setting
mode
- Register digital controller/diverter, see Function F3 - Register/de-
register
- Check transceiver or change position
- Deactivate potential source of interference and check function again
=> If positive reconfigure the interference source (eg wireless router)
- Rectify the fault see section Operating conditions
- Check installation or replace unit battery, see section Maintenance
- Wait until feeler gauge is cooling down
- Calibrate functional unit, see section F2 - Setting mode
- Wait 3 minutes, switch off the voltage supply and reconnect
- Switch off the voltage supply and consult a specialist installer
or the GROHE Service Hotline
- Switch off the voltage supply and consult a specialist installer
or return the product to GROHE