5.3
Connecting the adapter cable
Comply with the pin layout
Further information: "X1", Page 97
Remove and save the dust protection caps
Route the adapter cable based on the mounting variant
Check the seals of the connection or cable
Connect the connector to connection X1
Tighten the coupling ring of the connector (tightening
torque: 0.4 Nm to 0.6 Nm)
HEIDENHAIN | TD 110 | 05/2023
6
Specifications
6.1
Product data
Product
Housing
70 mm x 40 mm x 24 mm
dimensions
Type of
Mounting with two M5x25 cylinder
mounting
head screws
Electrical data
Supply voltage
DC 10 V ... 30 V (typical: DC 24 V)
8-pin M12 flange socket
Current
< 100 mA (without load)
consumption
HTL output
Triggering signals B, S, S
signal
(see"Image 0")
U
≥ (U
H
P
U
≤ 1.8 V at I
L
Floating trigger
NC, NO optocouplers (see "Image 0" )
outputs
Maximum rated voltage: DC 24 V
Maximum output current: 50 mA
Voltage drop at 50 mA: typ. 0.3 V
The current through the optocoupler must
be limited by a pull-up/pull-down resistor or a
suitable circuit.
– 2.2 V) at – I
≤ 20 mA
H
≤ 20 mA
L